H/L Voltage Clamp Meter
Model:ET-9000
Product Specification:
It has broken through the traditional structure, which is well-designed, specially for measuring high voltage current, adopting the latest CT technology and integrated mask digital technology, formed by composition of a special use clamp meter with a high-voltage insulation rod, as to ET-9000A type ---- infrared transmission of test data, also equipped with receivers, which can monitor the tested data in a long distance on real-time. If not using an insulation rod, it can be also used as a high precision low-voltage clamp meter, or an alternating current meter, which can accurately measure 1mA of current or leakage current.
It has an innovative integrated design between transducer clamp and transducer domain, ensuring the high-precision, high-reliability, and high-stability on constant test .
It is connected with insulation rod, which can be used for measuring high voltage current that is below 23KV, on-line current measurement, also has peak maintenance, data preservation, data storage, infrared transmission and other functions,its special clamp meter can make it easier to clamp or evacuate the tested wire through pressing or pulling back the insulation rod,which is time-saving and fast and widely used in transformer substation, power plant, industrial and mining enterprises as well as the inspection station and electrician maintenance departments for electrical current detection and field electrical operations. It can also replace the H/L voltage transforming ratio tester, that is, to detect the high and low current for primary circuit and secondary circuit separately, and then calculate to conclude the change of high and low pressure. The insulation rod is light and convenient, with the advantages of anti-moisture, high temperature resistance, anti-impact, bending resistance, high insulation, flexibility and other characteristics.
Technical Specifications:
Function |
High voltage AC current measurement, low voltage AC current, leakage current measurement, on-line AC current supervision. |
Power Supply |
DC6V Alkaline Dry Battery (1.5V AAA X 4) |
Test Method |
Clamp CT, Integral Method |
Transmission Method |
Infrared Transmission, the maximum distance for direct transmission is about 10 meters. |
Display Mode |
4 digital LCD display, backlight function, suitable for dark place. |
LCD Dimension |
47mm x 28.5mm |
Meter Dimension |
W/H/T: 76mm¡Á255mm¡Á31mm |
Clamp Diameter |
¦Õ48mm |
Sampling Speed |
Around 2 times/second |
Measurement Scope |
1mA 600A,50/60Hz, Auto Identification |
Resolution Rate |
1mA |
Measurement Range |
10A/600A, Double measurement ranges can be switched by manual, and it can be transferred automatically within each measurement range. |
Test Precision
23¡À5 Below 80%RH
|
1mA 299mA: ¡À1%¡À3dgt |
300mA 10.00A: ¡À1.5%¡À5dgt |
0.0A 49.9A: ¡À1.5%¡À5dgt |
50.0A 199.9A: ¡À2%¡À5dgt |
200A 399A: ¡À2.5%¡À5dgt |
400A 600A: ¡À3%¡À5dgt |
Circuit Voltage |
Test for the circuit below 23KV (operated with insulation rod) |
Data Memory |
99 Groups, during storage, the symbol ¡°MEM¡± gives indication, ¡°FULL¡± mark will flash to indicate the memory has been full. |
Peak Maintenance |
The function of automatic capture and maintain the maximum average value, under general test mode, press HOLD button longer till PEAK light is bright, that is, start PEAK test function, also known as peak test. |
Data Preservation |
Under general test mode, press HOLD button to preserve data, ¡°HOLD¡± symbol display. |
Data Reference |
¡°MR¡± symbol indicates that it can read the stored data by turning upwards and downwards. |
Overflow Display |
Exceed measurement range overflow function: ¡°OL A¡± symbol display |
No signal Indicator |
When the receiver has not received transmit signal, it will display ¡°no- -¡±signal dynamically. |
Auto Shut Down |
In about 15 minutes after booting, the meter will shut down automatically, in order to decrease the battery consumption. |
Battery Voltage |
When the battery voltage is below 4.8V, the symbol of battery voltage ¡° ¡±will show to replace battery. |
Meter Quality |
Tester: About 335g (Including battery), total quality of meter: about 2.5Kg (including insulation rod and battery.) |
Work Temperature and Moisture |
-10~40¡æ, Below 80%Rh |
Storage Temperature and Moisture |
-10~60¡æ, Below 70%Rh |
Insulation Rod Dimension |
¦Õ32mm, 1m/Section,5 Sections |
Insulation Intension |
AC 40KV/rms (Between insulation rod and clamp core) |
Structure |
Anti-Dripping Type II | |